Short version: Goodman, Janitrol, and GMC are three brand names stamped on cabinets that came off the same Houston assembly line. Goodman Manufacturing Company bought Janitrol in 1982 and used GMC as its own model-number prefix in the early years. That is why a Janitrol GMP gas furnace, a Goodman GMS cabinet, and a GMC110 condenser from the 1990s all take the exact same B1172605 flame sensor, 20165703S mini hot surface ignitor, PCBBF118S control board, and 0131F00006S inducer motor from the Goodman-Amana factory catalog. If the OEM part number stamped on the old component matches a current Goodman-Amana part, it fits.
This guide maps the legacy unit lines across the three brands and pairs each failure mode with the shared Goodman-Amana OEM part stocked at HVACMORE — with real 2026 prices and SKUs. For related brand-focused coverage, see the Furnace Buying Guide 2026, the Furnace Diagnosis Chat-Style guide, and the Control Board Visual Diagnosis guide.
Who are Goodman, Janitrol, and GMC?
Goodman Manufacturing Company was founded in Houston, Texas in 1975 by Harold V. Goodman. The original pitch was value HVAC: solid cabinets, standard-industry components, lower price than Carrier or Trane. By the mid-1980s Goodman was the fastest-growing residential HVAC manufacturer in the United States. Daikin Industries acquired Goodman in 2012 and continues to operate the brand out of a new Daikin Texas Technology Park facility in Waller, Texas.
Janitrol is older than Goodman. The brand started life as a Surface Combustion gas-heating product line in the 1930s, passed through Midland-Ross and Diversitronics ownership, and was acquired by Goodman in 1982. Goodman kept Janitrol as a second-tier brand on the same production lines through the 1990s and 2000s, and the brand quietly left new production around 2010. Janitrol replacement parts are still ordered under Goodman-Amana part numbers.
GMC is not a separate company. GMC stands for Goodman Manufacturing Company and was used as a model-number prefix on Goodman’s own residential furnaces, condensers, and heat pumps built roughly between 1982 and the mid-1990s. GMC110, GMC120, and GMC200 series were Goodman condenser model lines. GMP, GMPN, and GMPH were the matching gas furnace model lines. “GMC” stamped on an old condenser means Goodman — and the parts are identical to the later Goodman GSX, GSZ, and GMS equivalents.
For context, Goodman also bought Amana in 1997 and consolidated the parts lines, which is why HVACMORE catalogs the shared parts under a single Goodman-Amana vendor stamp. The Goodman-Amana collection at hvacmore.com/collections/goodman is where to start for any legacy Goodman, Janitrol, GMC, or compatible Amana unit.
Which legacy units did Goodman make under each brand?
Four product families run across all three brand stamps.
Gas furnaces. On the Goodman side, the model prefixes are GMP (early 80% efficiency), GMPN (natural-draft 80%), GMPH (horizontal 80%), GMS and GMSS (post-2000 80%), GMV and GMVC (90%+ condensing variable-speed), GMEC and GME (modulating). On the Janitrol side, the same cabinets were sold as GMP, GMPN, and GMPH through the 1990s. GMC was the Goodman internal model prefix for the same furnaces during the 1980s to mid-1990s window. All of them use the same shared parts platform.
Residential split condensers. Goodman model prefixes: CK, CKJ, CKL, CPLE (early), GSC (2000s), GSX (R-410A), GSX14, GSXC. Janitrol used CK and GCS model prefixes for the same equipment. GMC was the Goodman model prefix for the 1980s to mid-1990s condensers: GMC110, GMC120, GMC150, GMC200.
Residential heat pumps. Goodman: CPLJ, CPKJ (early), GSH, GSZ, GSZC. Janitrol: CPLJ and HP legacy prefixes. GMC: GMC110HP and matching heat pump stamps from the early years.
Air handlers. Goodman: ARUF, AWUF, AVPTC, AVPEC. Janitrol: ARUF legacy. These share evaporator coils and blower motors across the three brands.
In every case the cabinet brand on the door is cosmetic. The shared parts under the hood are what matter for repair, and those are catalogued under Goodman-Amana OEM part numbers.
Why the parts cross all three brands
Three reasons the parts are interchangeable.
Same factory, same production line. From 1982 onward Goodman built Goodman-, Janitrol-, and GMC-stamped cabinets on the same assembly tooling in Houston. The components that went into them — control boards, ignitors, flame sensors, inducer motors, blower motors, pressure switches, limit switches, gas valves — came from the same suppliers under the same part numbers. The brand on the door was a sales decision, not an engineering one.
Shared component suppliers. Goodman’s ignition controls came from White-Rodgers, Honeywell, and later from in-house Goodman manufacture. Hot surface ignitors came from Norton (now Saint-Gobain) and later Robertshaw. Flame sensors were in-house Goodman-Amana manufacture. Inducer motors came from Fasco, Jakel, and in-house. Blower motors came from GE/Genteq and Fasco. Pressure switches came from Tridelta and Cherry. The same supplier catalog shows up in Janitrol and GMC parts books because the cabinets were from the same line.
Backward-compatible superseding. When Goodman updated a part — for example, replacing an older ignition control board with a newer PCBBF-series board — the new part was engineered to drop into both Goodman and Janitrol cabinets without rewiring. That is how a Janitrol GMP furnace built in 1998 can take a Goodman PCBBF118S control board catalogued in 2026.
Shared control boards
The ignition control board is the brain of a residential gas furnace. On Goodman, Janitrol, and GMC units it is the single most expensive routine replacement after the compressor. HVACMORE stocks the Goodman-Amana ignition control board lineup that crosses all three brands.
The B1809923S is the classic one — the circuit board that shipped in Janitrol GMP, GMPN, and matching Goodman GMS cabinets through the 1990s and early 2000s. The PCBBF series boards (PCBBF118S, PCBBF124S, PCBBF149S) succeeded it on 80% and 90% furnaces from the mid-2000s onward. If the number on the old board does not match any of these, see the full Goodman-Amana collection or call HVACMORE at 855-575-4822.
Shared hot surface ignitors and spark ignitors
The hot surface ignitor fails on a predictable schedule — typically every 4 to 8 years on a Goodman, Janitrol, or GMC gas furnace — from thermal cycling fatigue. The silicon carbide and silicon nitride ignitors used across the Goodman platform are among the most commonly replaced components in the field.
The 20165703S mini hot surface ignitor is the single most-called-in part across all three brand platforms. On a 1990s Janitrol GMP or a 2000s Goodman GMS it is the same ignitor. If the furnace clicks, pauses, and then the inducer runs but no flame comes up, this is usually it. For diagnosis, see the Furnace Diagnosis Chat-Style guide.
Shared flame sensors
The flame sensor is a flat metal rod that sits in the flame envelope and sends a tiny microamp current back to the control board to confirm ignition. On Goodman, Janitrol, and GMC gas furnaces it is almost always the first thing to fail on an older cabinet — a $9 part that stops a $300 service call.
The B1172601 and B1172605 flame sensors cross the entire Goodman, Janitrol, and GMC gas furnace lineup from the late 1980s onward. If the furnace lights off, runs for 5 to 7 seconds, then shuts down and tries again, the flame sensor has oxidized and lost its microamp signal. A fine Scotch-Brite scrub often buys another winter; replacement is the permanent fix.
Shared inducer and blower motors
Inducer motors (also called draft inducers or vent motors) pull combustion products through the heat exchanger and exhaust them out the flue. On 80% and 90%+ Goodman, Janitrol, and GMC furnaces the same Fasco and Jakel inducers are used across the platform.
Match the exact OEM number stamped on the old motor housing before ordering. On older cabinets the sticker on the motor is often oil-soaked and unreadable — call HVACMORE at 855-575-4822 with the cabinet model and serial if that is the case.
Shared pressure switches and gas valves
The pressure switch confirms the inducer is actually pulling draft before the control board allows the gas valve to open. The gas valve opens on a 24V signal from the board to send gas to the burners. Both parts cross Goodman, Janitrol, and GMC gas furnace platforms.
For reversing valves on legacy Goodman, Janitrol, and GMC heat pumps, the 0151R00069SP reversing valve with coil and dryer at $134.77 is the common OEM replacement. For TXV service on R-410A split systems, see the R-410A Parts Replacement Guide 2026.
Worked example: Janitrol GMP075-3 that won’t fire
A homeowner calls about a 2001 Janitrol GMP075-3 upflow gas furnace. The symptom: the inducer kicks on, the ignitor glows, the gas valve clicks, flames come up for about 6 seconds, then shut off. The cycle repeats three times, then the furnace locks out and the LED on the board flashes a steady code.
Diagnosis. Flame rectification problem — the burner is lighting but the flame sensor is not seeing the flame. Classic Goodman/Janitrol platform symptom. The microamp reading on the flame sensor wire is 0.4 microamps; the minimum for the control board to lock in is 0.8 microamps. The sensor rod is oxidized gray-brown.
Part. Pull the flame sensor from the burner box, read the stamp: B1172605. That is a current Goodman-Amana OEM number — $8.70 at HVACMORE. Order one, swap it, light the furnace. Microamp reading on the fresh sensor is 4.8 microamps. Lockout clears, burners stay on, heat call completes.
Why this works. The Janitrol GMP075-3 and the Goodman GMS80703 that replaced it in 2003 share the same burner assembly and the same B1172605 flame sensor. The brand on the cabinet door does not matter — the part number on the component does.
For the step-by-step flame rectification diagnosis (voltage readings, microamp testing, scrubbing procedure vs replacement decision), see the Furnace Diagnosis Chat-Style guide.
When the OEM number on the data plate is discontinued
Legacy Janitrol and early GMC OEM parts have official Goodman-Amana supersessions. A supersession is a new current part number that replaces the obsolete one — electrically equivalent, physically compatible, and factory-authorized for the original cabinet. HVACMORE’s parts team maintains an internal cross-reference of these supersessions for the Goodman-Amana catalog.
To get the right supersession:
1. Have the cabinet model and serial ready. Both are on the data plate behind the blower door (furnace) or on the service panel (condenser or heat pump).
2. Have the old OEM number ready. Stamped on the part itself: the control board, the ignitor, the flame sensor, the inducer housing, the gas valve, or the pressure switch.
3. Call HVACMORE at 855-575-4822. The parts team will look up the current supersession in the Goodman-Amana master cross-reference. If a direct supersession is not available, a universal cross-reference (ICM Controls board, universal silicon carbide hot surface ignitor, standard 45/5 MFD 440V capacitor, generic 24V 30A 2-pole contactor) will almost always do the job for condenser and air-handler side parts. For the furnace control board specifically, OEM supersession is strongly preferred because the diagnostic LED fault codes and fan timing programming only match on genuine Goodman-Amana boards.
[Sourcing CTA image goes here — 27-sourcing-cta.svg. Delete this line after uploading.]
Browsing the full Goodman-Amana catalog
Everything in the sliders above and more is at hvacmore.com/collections/goodman. The collection covers Goodman, Janitrol, and GMC legacy parts under a single Goodman-Amana vendor stamp, organized by product type: control boards, pilot and ignition, flame sensors, pressure switches, gas valves, blower motors, blower assemblies, transformers, and more. If the OEM number stamped on the old part matches a current Goodman-Amana SKU, it ships from the HVACMORE warehouse.
For related brand-focused coverage on legacy and current units, see the Furnace Buying Guide 2026, the HVAC Repair vs Replace 2026 guide, and the HVAC Lifespan 2026 guide. For diagnosis across any brand, see the Furnace Diagnosis Chat-Style guide, the AC Diagnosis Chat-Style guide, and the Control Board Visual Diagnosis guide.
Frequently asked questions
Are Goodman and Janitrol the same company? Yes. Goodman bought Janitrol from Diversitronics in 1982 and ran the brand on the same Houston production lines until Janitrol-stamped units quietly left production around 2010. Daikin acquired Goodman in 2012.
What is GMC in Goodman HVAC? GMC stands for Goodman Manufacturing Company and was used as the model-number prefix on Goodman’s own early furnaces, condensers, and heat pumps from the 1980s to the mid-1990s (GMC110, GMC120, GMC200 condensers; GMP, GMPN, GMPH furnaces). Not a separate company.
Can I use a Goodman control board on a Janitrol furnace? Yes, if the OEM part number matches the one stamped on the old board. Common cross-fits include B1809923S, PCBBF118S, PCBBF124S, and PCBBF149S.
What is the most common failed part on a legacy Goodman, Janitrol, or GMC furnace? The flame sensor (B1172601 or B1172605, under $10). Second: the hot surface ignitor (20165703S at $52 or 11111701S at $105). Third: the ignition control board (B1809923S at $258 or PCBBF118S at $352).
Where is the data plate on a Goodman, Janitrol, or GMC furnace? Behind the blower door on the inside wall of the burner compartment. On condensers and heat pumps it is on the outside of the compressor service panel.
Can I replace a Janitrol gas valve with a Goodman gas valve? Yes, if the stamped number matches. Common Goodman-Amana cross-fits: 0151M00024S ($263.70 for 3.5” WC 24V single-stage) and 0151M00027SK ($110.34 for 2-stage).
Are Amana parts the same as Goodman and Janitrol? Many are, especially post-1997 after Goodman acquired Amana. HVACMORE lists them under a single Goodman-Amana vendor. Pre-1997 Amana may use different legacy numbers — call HVACMORE if the stamped number does not cross.
What inducer motor fits a Janitrol GMP series furnace? Most commonly 0131F00006S ($195.11), 0131G00000PS ($238.07), or B2833001S ($312.04). Match the stamped number on the old inducer housing before ordering.
Do Goodman and Janitrol condensers share capacitors and contactors? Yes. Standard industry MFD and amperage sizes — any Goodman-Amana, ICM Controls, or Mars 2 branded replacement in the correct MFD and voltage will fit.
What should I do if the Janitrol or GMC part number is discontinued? Call HVACMORE at 855-575-4822 with the old part number, the cabinet model, and the cabinet serial. The parts team can look up the current Goodman-Amana supersession or a universal cross-reference.
Need help identifying a legacy Goodman, Janitrol, or GMC part?
If the OEM number on the old part is faded, missing, or does not cross directly to a current Goodman-Amana SKU, call HVACMORE at 855-575-4822. Have the cabinet model number, serial number, and a photo of the old part ready. The parts team maintains an internal cross-reference of legacy Janitrol and GMC supersessions and can confirm the correct current OEM in a single call.
For orders by SKU directly, start at the Goodman-Amana collection. For broader diagnosis before swapping parts, see the Furnace Diagnosis Chat-Style guide and the Control Board Visual Diagnosis guide.
Sources
- Daikin Industries, Ltd. — Daikin corporate site (acquisition of Goodman in 2012)
- Goodman Manufacturing Company — goodmanmfg.com (current OEM parts catalog, model lookup)
- Amana HVAC — amana-hac.com (post-1997 Goodman subsidiary catalog)
- U.S. Environmental Protection Agency — Section 608 refrigerant handling
- U.S. Department of Energy — Furnaces and Boilers
- HVACMORE Goodman-Amana parts collection — hvacmore.com/collections/goodman
Prices and part availability pulled from hvacmore.com on 2026-10-23. Pricing and stock subject to change — verify at the linked product page before ordering, or call HVACMORE at 855-575-4822.
Ready to upgrade your system?
Free ZIP-based pricing on top-rated HVAC systems
Get instant local pricing and expert help choosing the right AC, furnace, or heat pump for your home.
Shop HVAC Systems